Air Filters Hepa SC Filter | Durable Industrial Air Filters - AccuraFil HEPA SC FILTER _ 24x24x12 | AccuraFil Air Filtration Skip to content

Premium Air Filtration for Industrial & Commercial Facilities

Help Line: (540)-520-4980

AccuraFil HEPA SC Filter | High-Efficiency HEPA Filters
Isometric view of a double turn flange HEPA Air filter with deep plated microglass media with labeled dimensions on a white background.
AccuraFil standard capacity HEPA air filter with deep pleated microglass fiber media and coated galvanized steel frame, designed for particulate filtration in commercial and industrial facilities like data centers, hospitals and cleanrooms.
Comparison chart of different AccuraFil HEPA Fiberglass air filters, showing filter images and key specifications for industrial and commercial use.

HEPA SC FILTER _ 24x24x12

$506.77From $286.13

Engineered Air Filters for Industrial & Commercial HVAC Systems

Select Filter Specifications:

HEPA-Actual Size: W x H x D (in.): Choose an option

HEPA-Actual Size: W x H x D (in.): Choose an option
24 x 24 x 11.5
23 3/8 x 23 3/8 x 11.5

HEPA Rating (EN 1822): Choose an option

HEPA Rating (EN 1822): Choose an option
H13 / 99.99%
E12 / 99.97%

HEPA-Frame Design: GI DTF - Neoprene Gasket on the Downstream Side

HEPA-Frame Design: GI DTF - Neoprene Gasket on the Downstream Side
GI DTF - Neoprene Gasket on the Downstream Side
Add to Wishlist
SKU:

icons of acceptable form of secured payment
Description
Standard Capacity HEPA Filter — E12 / H13 / H14 | AccuraFil
Quick Reference: The AccuraFil Standard Capacity (SC) HEPA Filter is a deep-pleat industrial air filter using glass fine microfiber media. Available in EN 1822 grades E12 (99.5% MPPS), H13 (99.95% MPPS), and H14 (99.995% MPPS). Rated airflow is 1200 CFM at 1.10 in wc initial pressure drop. Every unit is individually scan tested per EN 1822 with test results labeled and affixed to each filter. Frame options: GI, SS, AL, MDF. Maximum operating temperature: 80°C (176°F). UL Classified fire rating. SKU: ACC-HPA-SC. Manufactured by AccuraFil.

About This Product

Individually Certified Deep-Pleat HEPA Filtration for Critical Environments

  • AccuraFil Standard Capacity HEPA Filter utilizes micro glass fiber paper media arranged in deep pleats, delivering a large filtering area that ensures maximum airflow during high air volumes while maintaining the highest certified particulate removal performance.
  • Each filter undergoes individual scan testing per EN 1822 — not batch sampling — to ensure leak-proof performance across the entire filter face. Test results are documented, labeled, and affixed to each unit for full traceability in regulatory audits and cleanroom commissioning records.
  • Available in EN 1822 grades E12, H13, and H14, achieving MPPS efficiencies of 99.5%, 99.95%, and 99.995% respectively — with corresponding 0.3μ efficiencies of 99.97%, 99.99%, and 99.999% for cross-reference with ASHRAE specifications.
  • Standard galvanized steel frame as default, with optional SS, Aluminum, or MDF frames. Two-part polyurethane media sealant and seamless PU or Neoprene gasket provide a permanent leak-proof bond. UL Classified fire rating. Engineered for demanding industrial and commercial facilities.
🔬

Advanced Filtration Technology

  • Micro glass fiber paper media in a deep pleat design
  • Large filtering area for maximum airflow at high air volumes
  • EN 1822 grades E12, H13, H14 — up to 99.995% MPPS efficiency
  • Efficiency at 0.3μ: 99.97% / 99.99% / 99.999%
⚙️

Superior Construction

  • Standard GI steel frame; optional SS, AL, or MDF
  • Corrugated aluminum separators with hemmed edges for media protection
  • Two-part polyurethane media sealant for permanent leak-proof bonding
  • Seamless PU or Neoprene gasket options
🛡️

Reliable Performance

  • Individual scan tested per EN 1822 — every unit, not batch sampled
  • Test results labeled and affixed to each filter for full traceability
  • UL Classified fire rating
  • Engineered for demanding industrial and commercial facilities

Performance Attributes

Deep-Pleat Performance & Certified Integrity

  • Individual Scan Testing per EN 1822: Every filter is tested across its entire face using an aerosol photometer or particle counter to verify the absence of localised leaks in the media, frame seal, and gasket interface. Test results are documented and affixed to each unit — providing the traceable certification required for pharmaceutical GMP, hospital validation, and ISO cleanroom commissioning. This is the most rigorous form of HEPA certification: every unit, not a batch sample.
  • Deep-Pleat Large Filter Area: The deep pleat construction maximises effective media surface area within the filter depth, reducing face velocity and enabling high volumetric airflow at 1200 CFM and 1.10 in wc initial pressure drop — making it suited to high-capacity AHUs and recirculation systems with demanding airflow requirements.
  • Corrugated Aluminum Separators with Hemmed Edges: Precision-formed hemmed edges prevent separator migration and pleat convergence across the deep media pack, maintaining uniform airflow distribution and protecting the glass fiber media from damage throughout the filter's service life.

Technical Data

Technical Specifications & Compliance

Filter Type Deep Pleat Construction
Filter Grades (EN 1822)
E12 H13 H14
MPPS Efficiency 99.5% / 99.95% / 99.995%
Efficiency @ 0.3μ 99.97% / 99.99% / 99.999%
Rated Airflow 1200 CFM
Initial Pressure Drop 1.10 in wc
Filter Media Glass Fine Microfibers
Media Separator Corrugated Aluminum Separator (Hemmed Edges)
Frame Material SS / GI / AL / MDF
Media Sealant Two-Part Poly-Urethane
Gasket Seamless PU / Neoprene
Max Temperature 80°C (176°F)
Final Pressure Drop 2.00” wg (Recommended)
Fire Rating UL Classified
Testing Standard Individual Scan Tested per EN 1822

EN 1822 Filter Grade Tiers

EN 1822 E12 99.5% MPPS | 99.97% @ 0.3μ Industrial pre-filtration & light cleanroom applications
EN 1822 H13 99.95% MPPS | 99.99% @ 0.3μ Hospitals, pharma & ISO Class 5–7 cleanrooms
EN 1822 H14 99.995% MPPS | 99.999% @ 0.3μ ISO Class 3–4 cleanrooms & aseptic critical environments

Frame Material Options

GI Standard galvanized steel — general industrial and commercial applications
SS Stainless steel — pharmaceutical, food processing, and corrosive environments
AL Aluminum — weight-sensitive ceiling grids and module installations
MDF Non-metal construction where metallic frames are not specified

Key Performance Benefits

🔎 HEPA Deep Pleat Large media area maximises airflow and dust holding capacity at 1200 CFM
📋 Scan Tested Every unit individually scan tested per EN 1822 with affixed test report
🔥 UL Classified Fire-rated construction for demanding regulatory environments
🌡️ 80°C Max Temp Suitable for high-temperature industrial and process air applications

Industry Applications

Critical Industry Application Profiles

Pharmaceutical & Biotech

H13–H14 with individual scan certification for GMP manufacturing, aseptic filling, and ISO cleanroom terminal filtration. SS frame for CIP-compatible installations.

Hospitals & Healthcare

H13 / H14 for operating theatres, isolation rooms, and critical care. Individual EN 1822 scan test documentation satisfies hospital commissioning and validation requirements.

ISO Cleanrooms

H14 at 99.995% MPPS for ISO Class 3–4 environments. Deep-pleat format delivers high recirculation airflow with full per-unit certification traceability.

Industrial & Commercial AHUs

E12–H13 for demanding industrial facilities. Deep pleat maximises service interval between change-outs in high-volume continuous air handling applications.

Every Unit. Individual Scan Tested per EN 1822. Test results labeled and affixed — delivering traceable leak-proof HEPA performance from first installation to end of service life.

Selection Guide

How to Select the Right Standard Capacity HEPA Filter for Your Application

  1. Identify your EN 1822 grade requirement

    Select E12 (99.5% MPPS) for general industrial pre-filtration and light cleanroom applications. Select H13 (99.95% MPPS) for hospitals, pharmaceutical manufacturing, and ISO Class 5–7 cleanrooms. Select H14 (99.995% MPPS) for ISO Class 3–4 cleanrooms, aseptic environments, and critical containment applications demanding the highest certified sub-micron particle removal.

  2. Confirm individual scan test certification requirements

    For pharmaceutical GMP, hospital infection control, and cleanroom qualification, verify that individual scan testing per EN 1822 is required by your facility's validation protocol or procurement specification. AccuraFil Standard Capacity HEPA Filters are individually scan tested as standard, with test results labeled and affixed to each unit for full traceability.

  3. Select the frame material

    Choose GI (standard galvanized steel) for general industrial and commercial applications. Select SS for pharmaceutical, food processing, and corrosive environments. Choose AL for weight-sensitive ceiling grid or module installations. Specify MDF where non-metal construction is required by the facility or housing design.

  4. Select the gasket type and verify installation parameters

    Choose seamless polyurethane (PU) gasket for most cleanroom and HVAC applications. Select Neoprene where chemical resistance or specific compression characteristics are required by the housing specification. Confirm operating temperature does not exceed 80°C (176°F) and that the system supports the 2.00” wg recommended final pressure drop.

Product Comparison

Performance Comparison: Deep Pleat SC and HC HEPA vs. V-Bank HV HEPA

The HEPA HV Filter is the top-performing model in the AccuraFil range, utilizing a V-Bank mini-pleat design to provide the highest media surface area (291 sq.ft.). This allows it to handle 2000 CFM while maintaining the lowest resistance (1.05 in wc), offering superior airflow and energy efficiency compared to traditional deep-pleat designs.

In contrast, the HC HEPA and SC HEPA filters use deep-pleat designs. The HC supports 1700 CFM and the SC supports 1200 CFM — both at a 1.10 in wc initial pressure drop. All three models are available in the same EN 1822 grade range (E12, H13, H14); the choice depends on housing depth, target airflow volume, and energy efficiency priorities.

Frequently Asked Questions

Product FAQ

What EN 1822 grades are available and what do they mean?

EN 1822 is the European standard for HEPA and ULPA filters, using Most Penetrating Particle Size (MPPS) efficiency as the defining metric. AccuraFil's Standard Capacity HEPA Filter is available in three grades: E12 achieves 99.5% MPPS efficiency and is suited to general industrial and light cleanroom pre-filtration; H13 at 99.95% MPPS is the primary grade for hospitals, pharmaceutical manufacturing, and ISO Class 5–7 cleanrooms; H14 at 99.995% MPPS is required for ISO Class 3–4 cleanrooms, aseptic filling environments, and critical containment applications where the highest sub-micron particle removal is mandatory.

What is MPPS efficiency and why is it used instead of 0.3 micron efficiency for HEPA filters?

MPPS — Most Penetrating Particle Size — is the particle size at which a given filter media achieves its lowest efficiency. For glass fiber HEPA media, MPPS typically falls in the 0.1–0.3 micron range depending on fiber diameter and media structure. EN 1822 rates filters at MPPS because it represents the worst-case filtration scenario: if a filter meets its rated efficiency at MPPS, it will exceed that efficiency at all other particle sizes. MPPS efficiency is therefore a more rigorous and meaningful metric than fixed-particle-size efficiency alone. AccuraFil also provides efficiency at 0.3 microns for cross-reference with ASHRAE and legacy specifications.

What is individual scan testing per EN 1822 and why does it matter?

Individual scan testing per EN 1822 means every filter unit is tested across its entire face using an aerosol photometer or particle counter to verify that no localised leaks or pinholes exist in the media, frame seal, or gasket interface — not just statistically sampled from a production batch. Test results are documented and affixed to each filter unit, providing traceable proof of performance for regulatory audits, cleanroom qualification records, and commissioning documentation. For pharmaceutical, healthcare, and critical containment applications, individual scan test certification is typically a mandatory procurement requirement.

What is the difference between the Standard Capacity and High Capacity HEPA filter?

Both SC and HC HEPA filters share identical external dimensions and deep-pleat construction, differing only in pleat density. The HC model packs more media into the same footprint, increasing surface area and rated airflow to 1700 CFM versus 1200 CFM for the SC, while maintaining the same 1.10 in wc initial pressure drop. Choose HC where minimising change-out frequency is the primary requirement; choose SC for standard deep-pleat HEPA applications.

What frame and gasket options are available?

The AccuraFil Standard Capacity HEPA Filter is available with frames in GI (standard galvanized steel), SS (stainless steel for corrosive or pharmaceutical environments), AL (aluminum for weight-sensitive installations), and MDF (where non-metal construction is specified). Gasket options are seamless polyurethane or Neoprene, selected based on housing face seal requirements, chemical exposure, and temperature range. The two-part polyurethane media sealant provides a permanent, leak-proof bond between the media pack and frame throughout the filter's service life.